As a specialist roof waterproofing company Egypt operators rely on, we deliver engineered membrane and coating systems for commercial, industrial, and medical facilities across Cairo, 10th of Ramadan, 6th of October, Alexandria, the Delta, and the Canal cities. Our scope covers concrete decks, metal roofs, podium slabs, plant rooms, and utility tanks, addressing thermal shock, UV degradation, ponding, and structural movement typical of Egyptian climates. Every project begins with substrate diagnostics and moisture mapping, followed by system selection matched to substrate condition, service load, and reflectivity targets. We install certified products from Sika, Mapei, Koster, MC-Bauchemie, and BASF Master Builders, backed by documented QA/QC records and post-installation flood testing.
Our engineering team specifies waterproofing systems that meet EN and ASTM standards, ensuring long-term watertightness and thermal performance for logistics warehouses, pharmaceutical plants, hospitals, and food processing facilities. From torch-applied SBS membranes to seamless spray polyurea and heat-reflective acrylic coatings, each system is applied by trained crews with calibrated equipment and third-party verification. As a technically driven roof waterproofing company Egypt developers trust, we integrate insulation, screed-to-falls correction, and detailing at parapets, drains, HVAC curbs, and skylights into a single installation package. Deliverables include as-built drawings, batch traceability, adhesion testing, and a documented flood test report at handover, giving specifiers full compliance evidence.
- Certified systems from Sika, Mapei, Koster, MC-Bauchemie, BASF
- Documented flood testing and pull-off adhesion verification
- Heat-reflective coatings reducing rooftop surface temperatures
- Full detailing at parapets, drains, HVAC bases, skylights
- Compliance with EN and ASTM waterproofing standards



Which system fits your facility?
Torch-Applied Modified Bitumen Membrane
SBS/APP polymer-modified bitumen sheets torch-fused to primed decks at 3 to 5 mm thickness, providing high tensile strength, elastic recovery, and proven performance on large industrial roofs across Cairo and the Delta.
Spray-Applied Polyurea
Two-component pure polyurea sprayed at high pressure and temperature, curing in seconds to form a seamless, high-elongation membrane ideal for complex geometries, water tanks, and roofs subject to mechanical stress or ponding.
Polyurethane Spray Foam Insulation
Closed-cell polyurethane foam sprayed at 40 to 45 kg/m3 density, delivering combined thermal insulation and waterproofing on metal and concrete decks, reducing HVAC loads across warehouses in 6th of October and 10th of Ramadan.
Single-Component Liquid-Applied Polyurethane
Cold-applied moisture-curing polyurethane coating forming a monolithic, UV-stable membrane over complex details, suitable for pedestrian-trafficked roofs, plant rooms, and refurbishment projects requiring minimal disruption to ongoing operations.
Heat-Reflective Acrylic Coatings
Elastomeric acrylic coatings with high solar reflectance and emittance values per ASTM C1549, lowering rooftop surface temperatures on commercial buildings in Alexandria and Canal cities while providing secondary waterproofing protection.
Flexible Cementitious Systems
Two-component polymer-modified cementitious slurries for concrete decks, water tanks, and podium slabs, offering excellent adhesion, crack-bridging capability, and potable water compatibility using Koster and BASF Master Builders formulations.
Every commercial and industrial sector
Logistics and Distribution Warehouses
Pharmaceutical Manufacturing Plants
Hospitals and Medical Facilities
Food and Beverage Processing Plants
Commercial Office Towers
Shopping Malls and Retail Centers
Industrial Cold Storage Facilities
Water Treatment and Utility Tanks
Performance by the documented numbers
| Metric | Test Standard | Result |
|---|---|---|
| Membrane Thickness | ASTM D6164 | 3 to 5 mm |
| Spray Foam Density | ASTM D1622 | 40 to 45 kg/m3 |
| Surface Temperature Resistance | EN 1110 | Above 120 C |
| Acrylic Coating Performance | ASTM D6083 | Pass |
| Pull-Off Adhesion | ASTM D7234 | >1.5 MPa |
| Solar Reflectance | ASTM C1549 | ≥0.80 |
| Substrate Moisture Content | ASTM D4263 | <4% |
Our 8-step execution protocol
Roof Survey and Leak-Source Identification
Site walkover, infrared moisture scans, and core sampling to locate active leaks, saturated insulation, and failed laps.
Detail Inspection of Vulnerable Points
Systematic assessment of cracks, movement joints, drains, HVAC bases, parapets, and skylights to define the detailing scope.
Stripping and Deck Preparation
Removal of failed waterproofing layers, mechanical cleaning, and shot-blasting to expose sound substrate ready for treatment.
Crack Treatment and Corner Reinforcement
Routing and filling of cracks with polyurethane sealant and installation of fiberglass or polyester reinforcement at all internal corners.
Screed-to-Falls Correction
Application of lightweight polymer-modified screed to eliminate ponding zones and ensure minimum 1:80 fall toward drains.
Primer Application
Substrate-specific bituminous, epoxy, or polyurethane primer applied at manufacturer-specified coverage after ASTM D4263 moisture verification.
Waterproofing System Installation
Application of the selected membrane or coating at specified thickness under continuous QA/QC monitoring and wet-film gauge checks.
Flood Testing and Handover
48-hour flood test with monitored water level, followed by drainage, final inspection, and issuance of the handover report.
Why clients choose us
Manufacturer-Certified Applicators
Our crews hold current certifications from Sika, Mapei, Koster, MC-Bauchemie, and BASF Master Builders. This ensures warranties remain valid and installation follows verified technical data sheets.
Full QA/QC Documentation
Every project includes batch traceability, wet-film thickness logs, pull-off adhesion tests, and flood test reports. Specifiers receive a complete compliance dossier at handover.
Climate-Matched System Design
We specify systems engineered for Egyptian UV load, thermal cycling, and humidity in coastal Alexandria and Canal environments. Material selection reflects real operating conditions, not generic assumptions.
Integrated Insulation and Waterproofing
Our polyurethane spray foam and inverted roof systems combine thermal and moisture control in one package. This reduces HVAC load while eliminating vapor-drive delamination risks.
Nationwide Project Coverage
We mobilize crews and equipment across Cairo, 10th of Ramadan, 6th of October, Alexandria, the Delta, and Canal cities. Regional depots ensure rapid response for large industrial roofs.
Engineering-Led Diagnostics
Every scope begins with infrared surveys, core sampling, and substrate moisture testing before system selection. This eliminates guesswork and prevents recurring failures on refurbishment projects.